Title :
Compounding in synthetic aperture imaging
Author :
Hansen, J.M. ; Jensen, J.A.
Author_Institution :
Dept. of Electr. Eng., Tech. Univ. of Denmark, Lyngby, Denmark
fDate :
9/1/2012 12:00:00 AM
Abstract :
A method for obtaining compound images using synthetic aperture data is investigated using a convex array transducer. The new approach allows spatial compounding to be performed for any number of angles without reducing the frame rate or temporal resolution. This important feature is an intrinsic property of how the compound images are constructed using synthetic aperture data and an improvement compared with how spatial compounding is obtained using conventional methods. The synthetic aperture compound images are created by exploiting the linearity of delay-and-sum beamformation for data collected from multiple spherical emissions to synthesize multiple transmit and receive apertures, corresponding to imaging the tissue from multiple directions. The many images are added incoherently, to produce a single compound image. Using a 192-element, 3.5-MHz, λ-pitch transducer, it is demonstrated from tissue-phantom measurements that the speckle is reduced and the contrast resolution improved when applying synthetic aperture compound imaging. At a depth of 4 cm, the size of the synthesized apertures is optimized for lesion detection based on the speckle information density. This is a performance measure for tissue contrast resolution which quantifies the tradeoff between resolution loss and speckle reduction. The speckle information density is improved by 25% when comparing synthetic aperture compounding to a similar setup for compounding using dynamic receive focusing. The cystic resolution and clutter levels are measured using a wire phantom setup and compared with conventional application of the array, as well as to synthetic aperture imaging without compounding. If the full aperture is used for synthetic aperture compounding, the cystic resolution is improved by 41% compared with conventional imaging, and is at least as good as what can be obtained using synthetic aperture imaging without compounding.
Keywords :
biological tissues; biomedical transducers; biomedical ultrasonics; image resolution; phantoms; λ-pitch transducer; clutter levels; conventional methods; convex array transducer; cystic resolution; delay-and-sum beamformation; depth 4 cm; frame rate; frequency 3.5 MHz; medical ultrasound; multiple spherical emissions; multiple transmit aperture; receive aperture; spatial compounding; speckle information density; synthetic aperture imaging data; temporal resolution; tissue contrast resolution; tissue imaging; tissue-phantom measurements; wire phantom setup; Apertures; Compounds; Focusing; Image resolution; Speckle; Transducers; Artifacts; Image Processing, Computer-Assisted; Models, Biological; Phantoms, Imaging; Signal-To-Noise Ratio; Transducers; Ultrasonography;
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
DOI :
10.1109/TUFFC.2012.2427