DocumentCode
1291767
Title
Equivalent reactance of synchronous machines
Author
Crary, S. ; . March, L. ; Shildneck, L.P.
Author_Institution
General Electric Company, Schenectady, N. Y.
Volume
53
Issue
1
fYear
1934
Firstpage
124
Lastpage
132
Abstract
Steady state characteristics of synchronous machines of normal design are affected appreciably by changes in magnetic saturation. In this paper the effect of saturation is included in the derivation of the equations for determining steady state performance. It is shown that a saturated machine under steady state conditions, and for small changes from the original operating point, can be replaced for purposes of calculation by an unsaturated machine.
fLanguage
English
Journal_Title
Electrical Engineering
Publisher
ieee
ISSN
0095-9197
Type
jour
DOI
10.1109/EE.1934.6540376
Filename
6540376
Link To Document