• DocumentCode
    1293439
  • Title

    Pyrochemical behavior of cellulose insulation

  • Author

    Clark, F

  • Author_Institution
    General Electric Co., Pittsfield, Mass.
  • Volume
    54
  • Issue
    10
  • fYear
    1935
  • Firstpage
    1088
  • Lastpage
    1094
  • Abstract
    Tests on unbleached unsized linen paper of high purity indicate that the physical defects implied by the various pyroelectric theories of insulation failure appear secondary to, and manifested as a result of, the chemical changes involved. These chemical changes result in both increased power factor and decreased dielectric strength of the insulation. The investigation shows that chemical results of overheating of cellulose insulation in service may be disastrous even within a range of temperatures not generally associated with dangerous physical effects.
  • fLanguage
    English
  • Journal_Title
    Electrical Engineering
  • Publisher
    ieee
  • ISSN
    0095-9197
  • Type

    jour

  • DOI
    10.1109/EE.1935.6540719
  • Filename