Abstract
The standard apparatus used to calibrate ac voltmeters in the USSR is described. The test system uses 2 sets of thermoelectric voltage converters rated for voltage values of 0.3, 1, 3, and 10 V over the frequency range of 20 Hz to 30 MHz. The high-frequency converters use vacuum single-components with metal-film resistors. Techniques used to establish the accuracy and precision of the test apparatus are discussed and the results of these investigations are then presented.
Keywords
Accuracy; Calibration; Frequency conversion; Standards; Voltage control; Voltage measurement; Voltmeters;