• DocumentCode
    129416
  • Title

    Dual frequency transducers for intravascular ultrasound super-harmonic imaging and acoustic angiography

  • Author

    Jianguo Ma ; Xiaoning Jiang ; Martin, Karl H. ; Dayton, Paul A. ; Yang Li ; Qifa Zhou

  • Author_Institution
    Dept. of Mech. & Aerosp. Eng., North Carolina State Univ., Raleigh, NC, USA
  • fYear
    2014
  • fDate
    3-6 Sept. 2014
  • Firstpage
    675
  • Lastpage
    678
  • Abstract
    Imaging of coronary vasa vasorum may lead to assessment of the vulnerable plaque development in diagnosis of atherosclerosis diseases. Intravascular ultrasound (IVUS) imaging transducers capable of detecting microvessels via nonlinear contrast imaging could provide valuable diagnostic information, however such transducers are not yet produced commercially. Dual-frequency transducers capable of detection of microbubble super-harmonics have shown promise as a new contrast-enhanced IVUS (CE-IVUS) platform. Contrast-to-tissue ratio (CTR) in CE-IVUS imaging can be closely associated with the low frequency transmitter performance. In this paper, multiple dual frequency IVUS transducers with different transmission frequencies (6.5 and 5 MHz) and different materials (PMN-PT single crystals and 1-3 composite) were developed and evaluated. All transducer structures were constructed with the 30 MHz high frequency reception element in front of the low frequency transmission element. Super-harmonic imaging was carried out using a tissue mimicking phantom. With similar peak negative pressures, the lower transmission frequency transducers generated higher CTR (23 dB for 5 MHz transmission). With similar input excitations, the PMN-PT 1-3 composite produced higher resolution (70 μm for 1-cycle burst excitation) than single crystal ones (> 150 μm). Dual frequency transducers with 5 MHz transmitters made of PMN-PT 1-3 composite are preferable in the CE-IVUS imaging.
  • Keywords
    biological tissues; biomedical transducers; biomedical ultrasonics; biomimetics; diseases; image resolution; medical image processing; phantoms; ultrasonic imaging; ultrasonic transducers; CTR; IVUS imaging transducers; PMN-PT single crystals; acoustic angiography; atherosclerosis diseases diagnosis; composite materials; contrast-enhanced IVUS platform; contrast-to-tissue ratio; coronary imaging; coronary vasa vasorum; diagnostic information; dual frequency transducers; frequency 5 MHz; intravascular ultrasound imaging transducers; intravascular ultrasound super-harmonic imaging; low frequency transmission element; low frequency transmitter performance; lower transmission frequency transducers; microbubble super-harmonics detection; microvessel detection; multiple dual frequency IVUS transducers; nonlinear contrast imaging; super-harmonic imaging; tissue mimicking phantom; transducer structures; transmission frequencies; vulnerable plaque development; Acoustics; Angiography; Crystals; Image resolution; Transducers; Ultrasonic imaging; acoustic angiography; contrast super-harmonic imaging; dual frequency transducer; intravascular ultrasound; ultrasound transducers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2014 IEEE International
  • Conference_Location
    Chicago, IL
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2014.0166
  • Filename
    6931947