DocumentCode :
1294216
Title :
The calibration and use of directional couplers without standards
Author :
Allred, C.M. ; Manney, C.H.
Author_Institution :
Electromagnetics Div., Nat. Bur. of Stand., Boulder, CO, USA
Issue :
1
fYear :
1976
fDate :
3/1/1976 12:00:00 AM
Firstpage :
84
Lastpage :
89
Abstract :
Basic principles and suggested techniques are presented for calibrating nonideal four-port couplers without standards. Under the assumption that the complex ratio of the side-arm voltages are known, all the parameters, except one of the directional couplers, can be determined without recourse to known values of impedances, shorts, opens, etc. Also, the surprising number of measurements that can be made with such an incompletely calibrated coupler are discussed.
Keywords :
calibration; transmission lines; waveguide couplers; calibration; calibration technique; complex ratio; directional couplers; microwave couplers; nonideal four port couplers; parameter measurement; side arm voltages; Admittance; Admittance measurement; Directional couplers; Equations; Standards; Transmission line measurements;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/TIM.1976.6312311
Filename :
6312311
Link To Document :