  • Abstract
    A novel technique for output frequency linearization of a thermistor-astable multivibrator is presented. An analytical expression for the linearity condition is obtained and demonstrated experimentally. The astable multivibrator incorporating this technique is shown to offer an approximately linear temperature-to-frequency conversion in the range 0 to 86°C with a sensitivity of 21 Hz/°C. The experimental circuit exhibits excellent thermal stability for ambient temperature variations. The technique can also be used successfully in the lower temperature range -50 to 0°C.
  • Keywords
    convertors; multivibrators; temperature measurement; thermistors; -50 to 0Degrees C; 0 to 86Degrees C; linear temperature-to-frequency converter; output frequency linearization; temperature measurement; thermal stability; thermistor-astable multivibrator; Frequency measurement; Photodiodes; Temperature distribution; Temperature measurement; Temperature sensors; Thermistors; Voltage measurement;