• DocumentCode
    1295527
  • Title

    A fast local monitoring of dilute no by a tunable laser

  • Author

    Koga, Ryuji ; Kosaka, Megumi ; Sano, Hiroya

  • Author_Institution
    Dept. of Electronics, School of Engng., Okayama Univ., Okayama, Japan
  • Issue
    2
  • fYear
    1982
  • fDate
    6/1/1982 12:00:00 AM
  • Firstpage
    91
  • Lastpage
    96
  • Abstract
    Describes a real-time noncontacting, point-monitoring system for nitrogen monoxide. The monitoring system uses a grating-tuned pulsed dye laser and a specially developed microcomputer-assisted signal processor system. The system is sensitive for analyzing a gas concentration from 0.03 parts per million per meter (ppm/m) theoretically (which should be divided by an optical path length) to 0.4 ppm/m experimentally. The system reliability as well as the capability to detect sulfur dioxide which shares the spectral region with nitrogen monoxide was investigated.
  • Keywords
    air pollution detection and control; chemical variables measurement; computerised monitoring; geophysics computing; measurement by laser beam; nitrogen compounds; SO2 monitoring; air pollution monitoring; dilute NO monitoring; grating-tuned pulsed dye laser; local monitoring; microcomputer-assisted signal processor system; real-time noncontacting, point-monitoring system; Absorption; Hydrogen; Masers; Measurement by laser beam; Monitoring; Noise; Wavelength measurement;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.1982.6312528
  • Filename
    6312528