• DocumentCode
    1295817
  • Title

    A high-accuracy 10 Hz-1 MHz automatic AC voltage calibration system

  • Author

    Oldham, Nile M. ; Parker, M.E. ; Young, Albert M. ; Smith, Alan G.

  • Author_Institution
    National Bureau of Standards, Gaithersburg, MD 20899
  • Issue
    4
  • fYear
    1987
  • Firstpage
    883
  • Lastpage
    887
  • Abstract
    An automatic system for calibrating high-accuracy ac voltmeters and calibrators is described. The system is based on traditional coaxial, thermal voltage converters to provide ac voltage measurement uncertainties of 5–20 ppm in the audiofrequency range and 5–250 ppm over the full range from 10 Hz to 1 MHz at voltages between 0.5–600 V. Lower levels (0.01–0.5 V) are realized using wideband inductive dividers. Specialized hardware and measurement techniques make it possible to achieve these uncertainties in test periods of approximately 1 min. Random errors introduced by the measurement system are typically less than 2 ppm (one standard deviation).
  • Keywords
    Calibration; Frequency measurement; Measurement uncertainty; Probes; Standards; Uncertainty; Voltage measurement;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.1987.6312575
  • Filename
    6312575