DocumentCode
1295817
Title
A high-accuracy 10 Hz-1 MHz automatic AC voltage calibration system
Author
Oldham, Nile M. ; Parker, M.E. ; Young, Albert M. ; Smith, Alan G.
Author_Institution
National Bureau of Standards, Gaithersburg, MD 20899
Issue
4
fYear
1987
Firstpage
883
Lastpage
887
Abstract
An automatic system for calibrating high-accuracy ac voltmeters and calibrators is described. The system is based on traditional coaxial, thermal voltage converters to provide ac voltage measurement uncertainties of 5–20 ppm in the audiofrequency range and 5–250 ppm over the full range from 10 Hz to 1 MHz at voltages between 0.5–600 V. Lower levels (0.01–0.5 V) are realized using wideband inductive dividers. Specialized hardware and measurement techniques make it possible to achieve these uncertainties in test periods of approximately 1 min. Random errors introduced by the measurement system are typically less than 2 ppm (one standard deviation).
Keywords
Calibration; Frequency measurement; Measurement uncertainty; Probes; Standards; Uncertainty; Voltage measurement;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/TIM.1987.6312575
Filename
6312575