DocumentCode
1296005
Title
A new six-port calibration method using four standards and avoiding singularities
Author
Ghannouchi, Fadhel M. ; Bosisio, Renato G.
Author_Institution
Département de Génie Electrique, Ecole Polytechnique de Montréal, C. P. 6079, Station “A”, Montréal, Québec, Canada H3C 3A7
Issue
4
fYear
1987
Firstpage
1022
Lastpage
1027
Abstract
An alternative explicit linear method using four known standards is presented. The calibration parameters are obtained using only linear equation techniques to facilitate encoding the computation in low-level computer language. The method shows that no singularities appear over the calibration frequency range contrary to other methods using the same reflectometer.
Keywords
Calibration; Computer simulation; Junctions; Standards; Vectors;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/TIM.1987.6312603
Filename
6312603
Link To Document