• DocumentCode
    1296410
  • Title

    Absolute determination of the farad and the ohm, and measurement of the quantized Hall resistance RH(2) at LCIE

  • Author

    Delahaye, F. ; Fau, A. ; Dominguez, D. ; Bellon, M.

  • Author_Institution
    Laboratoire Central des Industries Electriques, Fontenay-aux-Roses, France
  • Issue
    2
  • fYear
    1987
  • fDate
    6/1/1987 12:00:00 AM
  • Firstpage
    205
  • Lastpage
    207
  • Abstract
    A calculable five-electrode cylindrical capacitor is used at Laboratoire Central des Industries Electriques (LCIE) for the absolute determination of the farad. The ac measurements linking the calculable standard to the resistors of a quadrature bridge are made at two different frequencies: ω = 2500 rad /s and ω = 5000 rad/s. The resistors of the quadrature bridge are linked to ΩLCIE and to the quantized Hall resistance RH(2) thanks to a resistance ratio measurement bridge using a cryogenic dc current comparator. The total one-standard-deviation (1σ) uncertainty on the measurement of RH(2) is 2.2 × 10−7.
  • Keywords
    Bridge circuits; Capacitors; Current measurement; Electrical resistance measurement; Resistance; Resistors; Standards;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.1987.6312669
  • Filename
    6312669