DocumentCode
1296488
Title
The Chinese 2e/h precision determination: China establishes its National Josephson Voltage Standard
Author
Chieh, Kao ; Chao-Jun, Zhang ; Guo-Lin, Zhung ; De-Ming, Duan ; Guang-Cai, Zhang ; Yu-Qing, Zhou ; Wu, Li ; Jian-Guo, Qu
Author_Institution
National Institute of Metrology, Dayi County, Sichuan, China
Issue
2
fYear
1987
fDate
6/1/1987 12:00:00 AM
Firstpage
262
Lastpage
264
Abstract
A measuring system for the precise determination 2e/h has been established recently and the National Voltage Standard using Josephson effect has been legally adopted in China. The total uncertainty of the measurement system is 3 × 10−8 with an accuracy of 1.1 × 10−7 for the value of 2e/h. The final experimental result is 2e/h = (483 593.846 ± 0.053) GHz/V83-NIM , referred to the volt as maintained by the National Institute of Metrology (NIM), Dayi County, Sichuan, China after January 1, 1983.
Keywords
Current measurement; Junctions; Resistors; Standards; Temperature measurement; Uncertainty; Voltage measurement;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/TIM.1987.6312682
Filename
6312682
Link To Document