DocumentCode
1296569
Title
AC-DC difference measurements on thermal voltage converters at NRC
Author
Matsumura, Tetsuo ; Clark, Richard F.
Author_Institution
National Research Council of Canada, Division of Physics, Ottawa, Ont., Canada K1A OR6
Issue
2
fYear
1987
fDate
6/1/1987 12:00:00 AM
Firstpage
333
Lastpage
336
Abstract
Two measurement systems are used at the National Research Council (NRC) of Canada to compare the ac-dc transfer differences δ of thermal voltage converters (TVC´s). One comparator operates from 25 Hz to 1 MHz, and the other from 50 kHz to 100 MHz. The standards for measurement of δ are groups of multijunction TVC´s at low frequency and a calorimetrie TVC at high frequency.
Keywords
Accuracy; Calibration; Connectors; Frequency measurement; Radio frequency; Standards; Voltage measurement;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/TIM.1987.6312696
Filename
6312696
Link To Document