• DocumentCode
    1296569
  • Title

    AC-DC difference measurements on thermal voltage converters at NRC

  • Author

    Matsumura, Tetsuo ; Clark, Richard F.

  • Author_Institution
    National Research Council of Canada, Division of Physics, Ottawa, Ont., Canada K1A OR6
  • Issue
    2
  • fYear
    1987
  • fDate
    6/1/1987 12:00:00 AM
  • Firstpage
    333
  • Lastpage
    336
  • Abstract
    Two measurement systems are used at the National Research Council (NRC) of Canada to compare the ac-dc transfer differences δ of thermal voltage converters (TVC´s). One comparator operates from 25 Hz to 1 MHz, and the other from 50 kHz to 100 MHz. The standards for measurement of δ are groups of multijunction TVC´s at low frequency and a calorimetrie TVC at high frequency.
  • Keywords
    Accuracy; Calibration; Connectors; Frequency measurement; Radio frequency; Standards; Voltage measurement;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.1987.6312696
  • Filename
    6312696