• DocumentCode
    129777
  • Title

    An array transmitter for dual-frequency contrast enhanced intravascular ultrasound imaging

  • Author

    Zhuochen Wang ; Jianguo Ma ; Xiaoning Jiang ; Martin, Karl H. ; Dayton, Paul A.

  • Author_Institution
    North Carolina State Univ., Raleigh, NC, USA
  • fYear
    2014
  • fDate
    3-6 Sept. 2014
  • Firstpage
    2104
  • Lastpage
    2107
  • Abstract
    Recent studies suggests that contrast ultrasound for molecular imaging or vasa vasorum (VV) assessment may be promising in identification of vulnerable plaques. However, conventional intravascular ultrasound (IVUS) transducers with frequency of 15 MHz - 60 MHz are not optimized for imaging with micro bubble contrast agents due to the ineffective micro bubble excitation at high frequencies and poor signal separation from tissue. This paper presents design and fabrication of a lateral mode transducer array with center frequency of 2 MHz for contrast enhanced IVUS (CE-IVUS) imaging, which can generate sufficient pressure to excite microbubbles more effectively and therefore could be used for dual-frequency microbubble superharmonic imaging, or `acoustic angiography´. Several commercial transducers with central frequency of 15 MHz, 20 MHz and 25 MHz were used as receivers to receive the contrast signal. In the contrast testing, the high frequency echo of the nonlinear response from microbubbles in a micro-tube with diameter of 0.2 mm was detected. The maximum contrast to noise ratio was 12.2 dB. The results show that superharmonic signals (over 9th harmonic) can be received; suggesting good resolution and signal separation in contrast enhanced IVUS imaging.
  • Keywords
    biomedical ultrasonics; ultrasonic transducer arrays; CE-IVUS imaging; acoustic angiography; array transmitter; contrast enhanced IVUS; contrast testing; dual-frequency contrast enhanced intravascular ultrasound imaging; frequency 15 MHz to 60 MHz; ineffective microbubble excitation; intravascular ultrasound transducers; lateral mode transducer array; micro bubble contrast agents; microbubble superharmonic imaging; molecular imaging; receivers; vasa vasorum assessment; vulnerable plaques; Acoustics; Arrays; Image resolution; Imaging; Noise; Transducers; Ultrasonic imaging; acoustic angiography; contrast ultrasound; lateral mode transducer; superharmonic; transmitting array transducer;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2014 IEEE International
  • Conference_Location
    Chicago, IL
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2014.0524
  • Filename
    6932235