• DocumentCode
    1297952
  • Title

    Measurement of transmitter harmonics

  • Author

    Eckersley, Alfred

  • Author_Institution
    Ark Electronics Corp. Willow Grove, Pa.
  • Issue
    1
  • fYear
    1961
  • fDate
    5/1/1961 12:00:00 AM
  • Firstpage
    40
  • Lastpage
    41
  • Abstract
    A topic of concern in the measurement of “antenna conducted” spurious and harmonic outputs of transmitters is the means of coupling the measuring instrument to the output line when the output is coaxial. A variety of techniques is observed in current specifications and practices. Essentially, they amount to a “probe” method, in which an inductive or capacitive pickup device (this includes waveguide-below-cutoff “Tee” attenuators) responds to the field in the line, a directional coupler which is connected to respond to the forward wave, or some sort of attenuator or voltage-divider network which is integral with a dummy load.
  • fLanguage
    English
  • Journal_Title
    Radio Frequency Interference, IRE Transactions on
  • Publisher
    ieee
  • ISSN
    0099-4545
  • Type

    jour

  • DOI
    10.1109/RFI.1961.6541600
  • Filename
    6541600