DocumentCode
1297952
Title
Measurement of transmitter harmonics
Author
Eckersley, Alfred
Author_Institution
Ark Electronics Corp. Willow Grove, Pa.
Issue
1
fYear
1961
fDate
5/1/1961 12:00:00 AM
Firstpage
40
Lastpage
41
Abstract
A topic of concern in the measurement of “antenna conducted” spurious and harmonic outputs of transmitters is the means of coupling the measuring instrument to the output line when the output is coaxial. A variety of techniques is observed in current specifications and practices. Essentially, they amount to a “probe” method, in which an inductive or capacitive pickup device (this includes waveguide-below-cutoff “Tee” attenuators) responds to the field in the line, a directional coupler which is connected to respond to the forward wave, or some sort of attenuator or voltage-divider network which is integral with a dummy load.
fLanguage
English
Journal_Title
Radio Frequency Interference, IRE Transactions on
Publisher
ieee
ISSN
0099-4545
Type
jour
DOI
10.1109/RFI.1961.6541600
Filename
6541600