DocumentCode
1300570
Title
Human failure considerations in determining an optimal inspection interval for equipment used in emergency conditions
Author
Anders, G.J.
Author_Institution
Ontario Hydro, Toronto, Ont., Canada
Issue
2
fYear
1985
Firstpage
290
Lastpage
294
Abstract
A mathematical model has been developed for determining an optimal inspection interval with human error considerations. The optimal inspection interval that maximizes the availability of equipment used in emergency conditions is sought. The human reliability model based on the technique for human error rate prediction (THERP) method is developed, and various levels of dependence between consecutive tasks are considered.
Keywords
human factors; inspection; reliability theory; emergency conditions; equipment availability; human error rate prediction; human reliability model; mathematical model; optimal inspection interval; Complexity theory; Detectors; Humans; Inspection; Maintenance engineering; Mathematical model; Reliability;
fLanguage
English
Journal_Title
Systems, Man and Cybernetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9472
Type
jour
DOI
10.1109/TSMC.1985.6313359
Filename
6313359