Human failure considerations in determining an optimal inspection interval for equipment used in emergency conditions
Author :
Anders, G.J.
Author_Institution :
Ontario Hydro, Toronto, Ont., Canada
Issue :
2
fYear :
1985
Firstpage :
290
Lastpage :
294
Abstract :
A mathematical model has been developed for determining an optimal inspection interval with human error considerations. The optimal inspection interval that maximizes the availability of equipment used in emergency conditions is sought. The human reliability model based on the technique for human error rate prediction (THERP) method is developed, and various levels of dependence between consecutive tasks are considered.
Keywords :
human factors; inspection; reliability theory; emergency conditions; equipment availability; human error rate prediction; human reliability model; mathematical model; optimal inspection interval; Complexity theory; Detectors; Humans; Inspection; Maintenance engineering; Mathematical model; Reliability;