DocumentCode :
1301717
Title :
Noninvasive evaluation of local myocardial thickening and its color-coded imaging
Author :
Kanai, Hiroshi ; Hasegawa, Hideyuki ; Chubachi, Noriyoshi ; Koiwa, Yoshiro ; Tanaka, Motonao
Author_Institution :
Dept. of Electr. Eng., Tohoku Univ., Sendai, Japan
Volume :
44
Issue :
4
fYear :
1997
fDate :
7/1/1997 12:00:00 AM
Firstpage :
752
Lastpage :
768
Abstract :
For the noninvasive diagnosis of heart disease based on the acoustic characteristics of the heart muscle, we have developed a new method for accurately tracking the movement of the heart wall. By this method, a velocity signal of the heart wall with a small amplitude of less than 10 /spl mu/m on the motion resulting from a heartbeat with large amplitude of 10 mm can be successfully detected with sufficient reproducibility in the frequency range up to several hundred Hertz continuously for periods of about 10 heartbeats. In this paper, the method is applied to multiple points preset in the left ventricular (LV) wall along the ultrasonic beam so that the spatial (depth) distributions of the velocity at these points are simultaneously obtained. The motion of the heart wall is divided into the following two components: parallel global motion of the heart wall and the change in myocardial layer thickening at each depth across the LV wall during myocardial contraction/relaxation. The latter component is superimposed on the M (motion) mode image using a color code to map contraction as red and expansion as blue. By preliminary human studies, the principle of the method proposed in this paper is verified and the frequency band of the components generated by thickening and/or thinning in the myocardium is identified. This new approach offers potential for research on noninvasive acoustical diagnosis of myocardial local motility, that is, the myocardial layer function at each depth in the ventricular wall.
Keywords :
biomedical ultrasonics; cardiology; muscle; color-coded imaging; heart disease; heart muscle; left ventricular wall; local myocardial thickening; noninvasive acoustical diagnosis; ultrasonic beam; Acoustic beams; Cardiac disease; Frequency; Heart beat; Motion detection; Muscles; Myocardium; Noninvasive treatment; Reproducibility of results; Tracking;
fLanguage :
English
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-3010
Type :
jour
DOI :
10.1109/58.655190
Filename :
655190
Link To Document :
بازگشت