• DocumentCode
    1310898
  • Title

    First performance results of PTB´s atomic caesium fountain and a study of contributions to its frequency instability

  • Author

    Weyers, Stefan ; Bauch, Andreas ; Hubner, Udo ; Schroder, Roland ; Tamm, Christian

  • Author_Institution
    Phys. Tech. Bundesanstalt, Braunschweig, Germany
  • Volume
    47
  • Issue
    2
  • fYear
    2000
  • fDate
    3/1/2000 12:00:00 AM
  • Firstpage
    432
  • Lastpage
    437
  • Abstract
    At the Physikalisch-Technische Bundesanstalt (PTB), an atomic caesium fountain was constructed. Ramsey fringes with a full width at half maximum (FWHM) of 0.86 Hz were obtained by launching the atoms to a height of 83 cm above the cooling region (40 cm above the microwave cavity center). A first measurement of the homogeneity of the magnetic flux density yields 0.33 nT (rms), only 0.16% of the mean value of 0.205 /spl mu/T used in normal operation. The inherent elementary noise contributions of the fountain and of a thermal beam atomic clock are compared in some detail.
  • Keywords
    atomic clocks; caesium; frequency stability; frequency standards; Cs; PTB; Ramsey fringes; atomic caesium fountain; frequency instability; frequency standard; laser cooling; magnetic flux density; microwave cavity; noise; thermal beam atomic clock; Atom lasers; Atom optics; Atomic beams; Atomic clocks; Atomic measurements; Cooling; Frequency; Gunshot detection systems; Optical noise; Stationary state;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/58.827431
  • Filename
    827431