Phase and light shift determination in an optically pumped cesium beam frequency standard
Author
Makdissi, Ala´a ; Berthet, Jean-Paul ; De Clercq, Emeric
Author_Institution
BNM-Lab. Primaire du Temps et des Frequence, Obs. de Paris, Meudon, France
Volume
47
Issue
2
fYear
2000
fDate
3/1/2000 12:00:00 AM
Firstpage
461
Lastpage
465
Abstract
The determination of the phase shift and the light shift in our optically pumped Cs beam is reported here. We show that an error on the phase difference value determined by our fit method, without beam reversal, can be induced if the light shift is not taken into account. If the experimental data are corrected for the light shift, the results of the fit method are in very good agreement with the beam reversal results. This allows us to reduce the related uncertainty in the accuracy budget of our standard. The resulting overall accuracy of the standard is now estimated to be 6.3/spl times/10(-15).
Keywords
atomic clocks; caesium; frequency standards; optical pumping; Cs; cesium beam frequency standard; light shift; optical pumping; phase shift; Arm; Atomic beams; Frequency measurement; Laser excitation; Optical beams; Optical pumping; Phase measurement; Resonance; Resonant frequency; Uncertainty;