• DocumentCode
    1312174
  • Title

    Non-rigid summing of gated PET via optical flow

  • Author

    Klein, G.J. ; Reutter, B.W. ; Huesman, R.H.

  • Author_Institution
    Center for Functional Imaging, Lawrence Berkeley Lab., CA, USA
  • Volume
    44
  • Issue
    4
  • fYear
    1997
  • fDate
    8/1/1997 12:00:00 AM
  • Firstpage
    1509
  • Lastpage
    1512
  • Abstract
    A method for summing together datasets from gated cardiac PET acquisitions is described. Optical flow techniques are used to accurately model non-rigid motion present during the cardiac cycle so that a one-to-one mapping is found between each voxel of two gated volumes. Using this mapping, image summing can take place, producing a composite dataset with improved statistics and reduced motion-induced blur. Results using data from a gated cardiac study on a dog are presented
  • Keywords
    biomechanics; cardiology; image sequences; medical image processing; motion estimation; positron emission tomography; cardiac cycle; composite dataset; dog; gated PET; gated volumes; image summing; medical diagnostic imaging; motion compensation; motion-induced blur; nonrigid motion modeling; nonrigid summing; nuclear medicine; one-to-one mapping; optical flow; voxel; Heart; Image motion analysis; Image reconstruction; Isotopes; Motion estimation; Optical attenuators; Optical filters; Optical imaging; Pixel; Positron emission tomography;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.632704
  • Filename
    632704