Abstract :
Long counters are widely used as neutron fluence monitors for their flat response. However, a bulky neutron moderator is required to achieve the flat response, which can be a disadvantage for portability and an undesirable source of scattered neutrons. Reducing the size of the moderator degrades the flat response, especially for high-energy neutrons. We propose a new method to reduce the size of the moderator while keeping a flat response, and we develop a compact flat-response neutron detector. The detector consists of two small spherical 3 He proportional counters embedded at appropriate positions in a compact cylindrical polyethylene moderator. The sensitivity ratio between the two counters was adjusted to provide a flat response in the total outputs from the two counters. We demonstrated by MCNPX calculations and response measurements for Cf and Am-Be neutrons and monoenergetic neutrons that the present detector had a sensitivity comparable to long counters with a good flat response in a wide energy range up to 20 MeV while being only one-fifth of the weight of long counters. The positions of the effective center were determined as a function of neutron energy. We also proposed a method to evaluate the neutron energy using the detector, which will allow various new applications taking advantage of the ability to measure neutron fluence and energy at the same time.
Keywords :
Monte Carlo methods; helium-3 counters; neutron detection; Am-Be neutrons; Cf neutrons; MCNPX calculations; bulky neutron moderator; compact flat response neutron detector; cylindrical polyethylene moderator; high-energy neutrons; long counters; monoenergetic neutrons; neutron fluence monitors; scattered neutrons; spherical 3He proportional counters; Calibration; Detectors; Energy measurement; Helium; Neutrons; Radiation detectors; Sensitivity; Effective center; flat response; long counter; neutron energy evaluation; neutron fluence measurement;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2011.2163191
Filename :
6007067
Link To Document :
بازگشت