DocumentCode :
1312629
Title :
Higher steam pressures or pulverized coal?
Author :
Scheffler, Frederick A.
Author_Institution :
Fuller Engineering Company, New York
Volume :
41
Issue :
5
fYear :
1922
fDate :
5/1/1922 12:00:00 AM
Firstpage :
346
Lastpage :
350
Abstract :
The author assumes a hypothetical power or public service steam plant of 100,000-kw. nominal capacity and compares the cost of operation of such a plant on a basis of 250 lb. pressure and 600 deg. fahr. total steam temperature, and 400 lb. pressure and 700 deg. fahr. total steam temperature, when fired by stokers and pulverized coal. The results of the comparison indicate that, with much lower capital costs, even better thermal plant efficiency will pertain with the use of pulverized coal and the lower steam pressure than would be the case with the higher steam pressure plant, stoker fired.
Keywords :
Ash; Boilers; Coal; Feeds; Furnaces; Temperature;
fLanguage :
English
Journal_Title :
American Institute of Electrical Engineers, Journal of the
Publisher :
ieee
ISSN :
0360-6449
Type :
jour
DOI :
10.1109/JoAIEE.1922.6590914