Abstract :
A comparison of the direct and indirect measurements of induction machine efficiency from a collection of test data is presented in this article. The efficiency is computed from 1,000 induction motors rated 1-250 hp to show the relative accuracy of the methods. The Bland-Altman procedure for comparing measurement methods is used in the analysis.
Keywords :
induction motors; Bland-Altman procedure; direct measurement; indirect measurement; induction machine efficiency; induction motor efficiency; power 1 hp to 250 hp; test data collection; Induction motors; Loss measurement; Power generation; Power measurement;