DocumentCode :
1313086
Title :
30 T repeating pulsed field system for neutron diffraction
Author :
Nojiri, H. ; Motokawa, M. ; Takahashi, K. ; Arai, M.
Author_Institution :
Inst. for Mater. Res., Tohoku Univ., Sendai, Japan
Volume :
10
Issue :
1
fYear :
2000
fDate :
3/1/2000 12:00:00 AM
Firstpage :
534
Lastpage :
537
Abstract :
A capacitor bank of 60 kJ energy is employed as the power supply. A maximum current of 30 kA can be obtained every two seconds and the charging voltage is 10 kV. A Bitter type magnet with three-layer structure has been developed. Bitter plates made of Cu-Ag alloy are used as the conductor and thin fiber-reinforced-plastic sheets are used as the insulator between the Bitter plates. The height of the solenoid type magnet is about 22 cm and the inner bore is 3 cm. The weight is about 30 kg. The pulse duration time of the magnet is about 1 ms. A pulsed neutron-source at KEK was combined with this system and neutron diffraction experiments were made in very high magnetic fields above 25 T.
Keywords :
capacitor storage; electromagnets; magnetic fields; neutron diffraction; power supplies to apparatus; solenoids; 1 ms; 10 kV; 22 cm; 25 to 30 T; 3 cm; 30 T repeating pulsed field system; 30 kA; 30 kg; 60 kJ; Bitter type magnet; Cu-Ag alloy; capacitor bank; fiber-reinforced-plastic sheets; neutron diffraction; neutron diffraction experiments; power supply; solenoid type magnet; three-layer structure; Boring; Capacitors; Conductors; Diffraction; Insulation; Neutrons; Power supplies; Pulsed power supplies; Solenoids; Voltage;
fLanguage :
English