Title :
A polyimide-etalon thin film structure for all-optical high-frequency ultrasound transduction
Author :
Sheaff, C. ; Ashkenazi, S.
Author_Institution :
Dept. of Biomed. Eng., Univ. of Minnesota-Twin Cities, Minneapolis, MN, USA
fDate :
10/1/2012 12:00:00 AM
Abstract :
In this work, we have designed, fabricated, and tested an all-optical ultrasound transducer by integrating a photoabsorptive polyimide thin film into a Fabry-Pérot (etalon) high-frequency receiver. A 5-ns UV pulse was used for thermoelastic ultrasound generation in the polyimide film, and the transmission had a maximum amplitude of 4.3 MPa centered at 27 MHz with a fractional bandwidth of 107%. The device attained a noise-equivalent pressure of 1.3 Pa/ Hz in receive-only mode. When used in pulse-echo mode, the -6-dB upper cutoff frequency of the transmit/receive response reached 47 MHz. Basic imaging capabilities were also investigated by scanning the near-infrared probe beam across the device to create a 2 × 2 mm synthetic aperture. The imaging of targets placed at depths of 1.8 and 5.2 mm yielded estimates of 71 and 145 μm, respectively, for the lateral resolution and 35 and 38 μm, respectively, for the axial resolution. Finally, a design concept for a forward-viewing intravascular imager is presented that entails the coupling of light to a rotating, linear array of optical fibers on top of which are deposited polyimide- etalon transducers. Such a design would allow for a flexible and compact high-resolution imager well-suited for intravascular applications, such as guidance of treatment in the case of chronic total occlusion.
Keywords :
Fabry-Perot interferometers; biomedical transducers; biomedical ultrasonics; optical arrays; optical fibre fabrication; polymer films; thermoelasticity; ultrasonic transducers; Fabry-Perot high-frequency receiver; UV pulse; all-optical high-frequency ultrasound transduction; all-optical ultrasound transducer; chronic total occlusion; forward-viewing intravascular imager; frequency 27 MHz; frequency 47 MHz; high-resolution imager; intravascular application; near-infrared probe beam; noise-equivalent pressure; optical fiber linear array; photoabsorptive polyimide thin film; polyimide-etalon thin film structure; polyimide-etalon transducer; pulse-echo mode; receive-only mode; synthetic aperture; thermoelastic ultrasound generation; transmit-receive response; Acoustic beams; Acoustics; Films; Optical pulses; Optical resonators; Polyimides; Transducers; Imides; Infrared Rays; Polymers; Transducers; Ultrasonography;
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
DOI :
10.1109/TUFFC.2012.2450