Title :
Measured-loss analysis of superconducting power transmission cable
Author :
Hoshino, Takashi ; Yamaji, N. ; Muta, I. ; Nakamura, T. ; Higuchi, N. ; Natori, N. ; Fuchino, S. ; Arai, K.
Author_Institution :
Graduate Sch. of Eng., Kyoto Univ., Japan
fDate :
3/1/2000 12:00:00 AM
Abstract :
In the former work (see T.Hoshino et al., ibid., vol.9, no.2, pp.1277-80, 1999), the eddy current loss in the former due to pitch difference between current conductor and shield conductor was studied. The calculated value was negligible small which does not explain the measured value. The eddy current loss due to radial component of the magnetic field become comparable with the measured value. In this paper, the reason of the increased loss is revealed. The disturbance of the conductor pitch yields different strength of the axial magnetic field. The difference of the axial flux toward the radial direction as the radial component of the flux. The flux causes eddy current loss in the copper for stabilizer. It is well match with the measured value.
Keywords :
eddy current losses; superconducting cables; conductor pitch; copper stabilizer; current conductor; eddy current loss; magnetic field; shield conductor; superconducting power transmission cable; Cable shielding; Conductors; Current measurement; Eddy currents; Magnetic field measurement; Magnetic shielding; Power measurement; Power transmission; Superconducting cables; Superconducting transmission lines;
Journal_Title :
Applied Superconductivity, IEEE Transactions on