DocumentCode :
1314554
Title :
Effect of AC loss on quench propagation in impregnated magnets
Author :
Eyssa, Y.M. ; Melhem, Z.
Author_Institution :
Nat. High Magnetic Field Lab., Tallahassee, FL, USA
Volume :
10
Issue :
1
fYear :
2000
fDate :
3/1/2000 12:00:00 AM
Firstpage :
1380
Lastpage :
1383
Abstract :
Protection of epoxy impregnated magnets requires careful design and analysis of all factors that affect the winding temperature rise before it reaches quench temperature. Among these factors is the AC loss due to current and field change as a result of the current transfer between coils after the protection diodes voltages exceed their critical values. In this paper we look in detail into the effect of all loss components, self-field, hysteresis, and eddy current coupling using the National High Magnetic field Laboratory computer code MAGZIFT.
Keywords :
superconducting magnets; AC loss; NHMFL MAGZIFT computer code; current transfer; eddy current; epoxy impregnated magnet; hysteresis; protection diode; quench propagation; self-field; thermal model; winding temperature; Coils; Diodes; Eddy currents; Magnetic analysis; Magnetic hysteresis; Magnets; Propagation losses; Protection; Temperature; Voltage;
fLanguage :
English
Journal_Title :
Applied Superconductivity, IEEE Transactions on
Publisher :
ieee
ISSN :
1051-8223
Type :
jour
DOI :
10.1109/77.828495
Filename :
828495
Link To Document :