Title :
Effect of AC loss on quench propagation in impregnated magnets
Author :
Eyssa, Y.M. ; Melhem, Z.
Author_Institution :
Nat. High Magnetic Field Lab., Tallahassee, FL, USA
fDate :
3/1/2000 12:00:00 AM
Abstract :
Protection of epoxy impregnated magnets requires careful design and analysis of all factors that affect the winding temperature rise before it reaches quench temperature. Among these factors is the AC loss due to current and field change as a result of the current transfer between coils after the protection diodes voltages exceed their critical values. In this paper we look in detail into the effect of all loss components, self-field, hysteresis, and eddy current coupling using the National High Magnetic field Laboratory computer code MAGZIFT.
Keywords :
superconducting magnets; AC loss; NHMFL MAGZIFT computer code; current transfer; eddy current; epoxy impregnated magnet; hysteresis; protection diode; quench propagation; self-field; thermal model; winding temperature; Coils; Diodes; Eddy currents; Magnetic analysis; Magnetic hysteresis; Magnets; Propagation losses; Protection; Temperature; Voltage;
Journal_Title :
Applied Superconductivity, IEEE Transactions on