  • Title

    High accuracy field integral measurement for TJNAF beam energy determination

  • Author

    Kircher, F. ; Fabre, J. ; Gougnaud, F. ; Humeau, M. ; Leboeuf, R. ; Lussignol, Y. ; Marroncle, J. ; Matichard, G. ; Marchand, D. ; Sellier, J.C. ; Vernin, P. ; Veyssiere, C.

  • Author_Institution
    CEA, Centre d´Etudes Nucleaires de Saclay, Gif-sur-Yvette, France
  • Volume
    10
  • Issue
    1
  • fYear
    2000
  • fDate
    3/1/2000 12:00:00 AM
  • Firstpage
    1427
  • Lastpage
    1430
  • Abstract
    The determination of the beam energy in the experimental hall A of TJNAF (previously CEBAF) accelerator is done through a very accurate measurement of the field integral of a reference dipole magnet, electrically connected in series with the bending magnets transporting the beam from the accelerator to the experimental area. A new method is used to determine the field integral; this method is described, as well as the calibrations done in the laboratory. Finally, the goal to reach an accuracy of the field integral on the order of 10/sup -5/ has been reached, as it is shown by comparing the results of the beam energy determination obtained on the accelerator with this method to results obtained by other independant methods.
  • Keywords
    accelerator magnets; beam handling techniques; calibration; magnetic field measurement; CEBAF; TJNAF accelerator; TJNAF beam energy; arc dipole; bending magnets; field integral measurement; reference dipole; reference dipole magnet; Amplifiers; Coils; Energy measurement; Integral equations; Large Hadron Collider; Magnetic field measurement; Position measurement; Wire; Wounds;
  • fLanguage
    English
  • Journal_Title
    Applied Superconductivity, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1051-8223
  • Type

    jour

  • DOI
    10.1109/77.828507
  • Filename
    828507