• DocumentCode
    1314651
  • Title

    Magnetic field measurements of Fermilab main injector dipoles

  • Author

    Brown, B.C. ; DiMarco, J. ; Glass, H.D. ; Harding, David J. ; Martin, P.S. ; Mazur, P.O. ; Mishra, C.S. ; Orris, D.F. ; Sim, J.W. ; Tompkins, J.C. ; Trombly-Freytag, K. ; Walbridge, D.G.C.

  • Author_Institution
    Fermi Nat. Accel. Lab., Batavia, IL, USA
  • Volume
    10
  • Issue
    1
  • fYear
    2000
  • fDate
    3/1/2000 12:00:00 AM
  • Firstpage
    1431
  • Lastpage
    1434
  • Abstract
    Measurements of the Fermilab Main Injector dipoles using a partially redundant system of integrated and point measurements were carried out for quality assurance. Additional special measurements studied the hysteretic field strength. Results from these measurements are presented.
  • Keywords
    accelerator magnets; data acquisition; magnetic field measurement; quality control; FLATCOIL; Fermilab main injector dipoles; POINTSCAN; hysteretic field strength; integrated measurement; magnetic field measurement; point measurement; quality assurance; redundant system; Coils; Data acquisition; Glass; Magnetic field measurement; Magnets; Probes; Prototypes; Radio access networks; Testing; Voltage;
  • fLanguage
    English
  • Journal_Title
    Applied Superconductivity, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1051-8223
  • Type

    jour

  • DOI
    10.1109/77.828508
  • Filename
    828508