Abstract :
Measurements of the Fermilab Main Injector dipoles using a partially redundant system of integrated and point measurements were carried out for quality assurance. Additional special measurements studied the hysteretic field strength. Results from these measurements are presented.
Keywords :
accelerator magnets; data acquisition; magnetic field measurement; quality control; FLATCOIL; Fermilab main injector dipoles; POINTSCAN; hysteretic field strength; integrated measurement; magnetic field measurement; point measurement; quality assurance; redundant system; Coils; Data acquisition; Glass; Magnetic field measurement; Magnets; Probes; Prototypes; Radio access networks; Testing; Voltage;