Abstract :
The invariance of the wave equation under time-reversal (TR) in a lossless transmission line is exploited for the detection and localisation of soft faults in a wire network. An original TR signal processing is exposed and evaluated on numerical examples. This new wiring diagnosis´s effectiveness is discussed and pointed out.
Keywords :
fault diagnosis; signal processing; transmission lines; wave equations; wiring; TR signal processing; soft fault detection; soft fault localisation; time-reversal; wave equation; wire network; wiring diagnosis;