• DocumentCode
    1315687
  • Title

    Dimensional correction of high dielectric and magnetic constants determined by S parameters measurements

  • Author

    Henaux, J.C. ; Crozat, P.

  • Author_Institution
    Inst. d´Electron. Fondamentale, Univ. Paris Sud, Orsay, France
  • Volume
    26
  • Issue
    15
  • fYear
    1990
  • fDate
    7/19/1990 12:00:00 AM
  • Firstpage
    1151
  • Lastpage
    1153
  • Abstract
    The measurement of high dielectric constants materials in a coaxial line, using an automatic network analyser (ANA), must take the actual diameter of the sample into consideration. The error on the measured epsilon r value may be approximated by the fractional diameter deviation times epsilon r2. A correction method is proposed.
  • Keywords
    S-parameters; coaxial cables; magnetic permeability measurement; materials testing; measurement errors; microwave measurement; permittivity measurement; ANA; S parameters measurements; automatic network analyser; coaxial line; correction method; dimensional correction; fractional diameter deviation; geometrical correction; high permeability materials; high permittivity materials; measurement of high dielectric constants materials;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:19900745
  • Filename
    82915