DocumentCode
1315895
Title
Performance trade-offs in SAW group-type SPUDTs
Author
Morgan, D.P.
Volume
26
Issue
15
fYear
1990
fDate
7/19/1990 12:00:00 AM
Firstpage
1200
Lastpage
1201
Abstract
The centre-frequency conversion and reflection coefficients of a SPUDT can be deduced from the directivity if the electrical load is designed either for minimum conversion loss or for zero acoustic reflection. A 3 dB conversion loss is obtainable, with zero acoustic reflection, if the directivity is 3 dB.
Keywords
surface acoustic wave devices; ultrasonic transducers; SAW group-type SPUDTs; centre-frequency conversion; directivity; electrical load; minimum conversion loss; reflection coefficients; single-phase unidirectional transducers; zero acoustic reflection;
fLanguage
English
Journal_Title
Electronics Letters
Publisher
iet
ISSN
0013-5194
Type
jour
DOI
10.1049/el:19900776