DocumentCode
1317966
Title
Characterisation of electromagnetic fields in buildings
Author
Lau, P.-K.
Author_Institution
Bell-Northern Res., Ottawa, Ont., Canada
Volume
26
Issue
21
fYear
1990
Firstpage
1778
Lastpage
1779
Abstract
Cumulative distributions of both electric and magnetic fields are given for the indoor environment in Canada. The statistics indicate that an E-field strength susceptibility limit of 3 V/m corresponding to a cumulative probability level of 95.0%, and a susceptibility limit of 5 V/m, with a cumulative probability level of 99.2%, would be adequate for the territory covered. A gamma distribution model of the data is found to be superior to a Gaussian model.
Keywords
building; electromagnetic interference; Canada; E-field strength susceptibility limit; Gaussian model; buildings; cumulative probability level; electric field distribution; electromagnetic fields; electromagnetic interference; gamma distribution model; indoor environment; magnetic field distribution;
fLanguage
English
Journal_Title
Electronics Letters
Publisher
iet
ISSN
0013-5194
Type
jour
DOI
10.1049/el:19901141
Filename
83108
Link To Document