Title :
Characterisation of electromagnetic fields in buildings
Author_Institution :
Bell-Northern Res., Ottawa, Ont., Canada
Abstract :
Cumulative distributions of both electric and magnetic fields are given for the indoor environment in Canada. The statistics indicate that an E-field strength susceptibility limit of 3 V/m corresponding to a cumulative probability level of 95.0%, and a susceptibility limit of 5 V/m, with a cumulative probability level of 99.2%, would be adequate for the territory covered. A gamma distribution model of the data is found to be superior to a Gaussian model.
Keywords :
building; electromagnetic interference; Canada; E-field strength susceptibility limit; Gaussian model; buildings; cumulative probability level; electric field distribution; electromagnetic fields; electromagnetic interference; gamma distribution model; indoor environment; magnetic field distribution;
Journal_Title :
Electronics Letters
DOI :
10.1049/el:19901141