DocumentCode
1318043
Title
The Spatial and Temporal Distortion of Magnetic Fields Applied Inside a Magnetically Shielded Room
Author
Vesanen, Panu T. ; Nieminen, Jaakko O. ; Zevenhoven, Koos C J ; Dabek, Juhani ; Simola, Juha ; Sarvas, Jukka ; Ilmoniemi, Risto J.
Author_Institution
Dept. of Biomed. Eng. & Comput. Sci., Aalto Univ., Aalto, Finland
Volume
48
Issue
1
fYear
2012
Firstpage
53
Lastpage
61
Abstract
In the context of biomagnetism, a magnetically shielded room (MSR) is designed for shielding against external magnetic fields. Recently, several applications, such as combined structural magnetic resonance imaging (MRI) and functional magnetoencephalography (MEG), have emerged that require applying relatively strong magnetic fields inside the MSR. These magnetic fields induce eddy currents and magnetize the MSR walls that are made of materials with high permeability and conductivity. These eddy currents and magnetization generate secondary magnetic fields inside the room that disturb, e.g., combined MEG-MRI by affecting sample spins and by exceeding the available dynamic range of the magnetic field sensors. In this work, static and dynamic magnetic fields applied inside an MSR are studied both theoretically and experimentally. Using a spherical model, analytical expressions are derived for the amplitudes and time constants of the various secondary magnetic field modes. These predictions are validated by comparison with experimental measurements in a rectangular MSR. The results of this study facilitate, e.g., the design of coils compatible with an MSR; a self-shielded coil is presented that decreases the secondary magnetic fields to a small fraction.
Keywords
biomedical MRI; coils; eddy currents; magnetic shielding; magnetoencephalography; MEG-MRI; analytical expressions; biomagnetism; coil design; conductivity; dynamic magnetic field; eddy currents; external magnetic fields; functional magnetoencephalography; magnetic field sensors; magnetically shielded room; magnetization; permeability; rectangular MSR; secondary magnetic field modes; self-shielded coil; shielding; spatial distortion; spherical model; static magnetic field; structural magnetic resonance imaging; temporal distortion; time constants; Aluminum; Analytical models; Coils; Magnetic moments; Magnetic noise; Magnetic resonance imaging; Magnetic shielding; Eddy currents; MEG; MRI; magnetically shielded room;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/TMAG.2011.2167627
Filename
6016237
Link To Document