Title :
Bird protector-related issues on medium voltage overhead networks
Author :
Gocsei, Gabor ; Nemeth, Balazs ; Cselko, Richard ; Berta, Istvan
Author_Institution :
Budapest Univ. of Technol. & Econ., Budapest, Hungary
Abstract :
In the last few years bird protection became a more and more important aspect on medium voltage overhead lines. Injuries of birds related to electrocution endanger both the health of the different species and the reliability of the grid as well. International standards and national regulations based on the opinion of different associations for wildlife protection are often been accepted without any detailed inspection of equipment to be installed on the network. There are many types of insulators, cross-arms and poles even in a specific section of a medium voltage power line. The same type of rigid bird protector installed on them can easily increase the risk of failures caused by the wrong way of application or installation. A rigid bird protector - especially in case of rainy weather conditions or fog - acts as a floating object near the phase conductors. This electrode distorts the electric field distribution even in case of normal operational conditions and increase the risk of flashovers on the surface of the insulators caused by an overvoltage wave in the conductors. Use of conductor and insulator covers are also questionable from the aspect of live-line maintenance (LLM): inspection of working site became impossible and electrical and mechanical condition cannot been estimated at all. Operations with the hot stick method - which is a widely used LLM technique for example in Hungary - became especially difficult. Inspection of different bird protective equipment from electrical aspect is a very important question to keep the operation of medium voltage grids as reliable as possible. In the High Voltage Laboratory of Budapest University of Technology and Economics calculations, finite element simulations of electric field and potential on complex 3D CAD models and a set of measurements have been executed to inspect the exact effects of these equipment from the aspect of the reliability of the grid. Experimental studies in Hungary show that many failures are re- ated to rigid bird protectors. There are often detectable marks on the surface of both the phase conductors and insulators. There are many bird protector-related switch-offs on the territory of different Hungarian DSOs, so the clarification of unexplained questions about this practical topic is urgent and become more and more important.
Keywords :
failure analysis; finite element analysis; insulators; poles and towers; power cables; power grids; power overhead lines; power system reliability; risk analysis; Hungarian DSOs; LLM; bird protective equipment; bird protector-related issues; complex 3D CAD models; cross-arms; electric field distribution; electrical condition; electrocution; failure risk; finite element simulations; flashovers; fog; grid reliability; insulators; international standards; live-line maintenance; mechanical condition; medium voltage grids; medium voltage overhead lines; medium voltage overhead networks; medium voltage power line; national regulations; overvoltage wave; phase conductors; poles; rainy weather conditions; wildlife protection; working site inspection; Aging; Birds; Conductors; Design automation; Irrigation; Planning; Solid modeling; FEM simulation; bird protection; electric field; medium voltage; overhead lines;
Conference_Titel :
Live Maintenance (ICOLIM), 2014 11th International Conference on
Conference_Location :
Budapest
DOI :
10.1109/ICOLIM.2014.6934383