Abstract
The letter describes a fibre-optic mass flowmeter for liquids, which is based on the Coriolis effect. The flowmeter is optically powered, and employs interferometric detection. Experimental results are presented and discussed
Keywords
Coriolis force; fibre optic sensors; flowmeters; pipe flow; Coriolis effect; Coriolis mass flowmeter; fibre-optic mass flowmeter; interferometric detection; liquids; optically powered;