• DocumentCode
    1319361
  • Title

    Fibre-optic Coriolis mass flowmeter for liquids

  • Author

    Wade, C.A. ; Dandridge, A.

  • Author_Institution
    Naval Res. Lab., Washington, DC
  • Volume
    24
  • Issue
    13
  • fYear
    1988
  • fDate
    6/23/1988 12:00:00 AM
  • Firstpage
    783
  • Lastpage
    785
  • Abstract
    The letter describes a fibre-optic mass flowmeter for liquids, which is based on the Coriolis effect. The flowmeter is optically powered, and employs interferometric detection. Experimental results are presented and discussed
  • Keywords
    Coriolis force; fibre optic sensors; flowmeters; pipe flow; Coriolis effect; Coriolis mass flowmeter; fibre-optic mass flowmeter; interferometric detection; liquids; optically powered;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • Filename
    8329