• DocumentCode
    13207
  • Title

    Partial discharge characteristics over SF6/epoxy interfaces under impulse voltage

  • Author

    Junhao Li ; Liang Zhang ; Jianfeng Liang ; Xiu Yao ; Yanming Li

  • Author_Institution
    State Key Lab. of Electr. Insulation & Power Equip., Xi´an Jiaotong Univ., Xi´an, China
  • Volume
    20
  • Issue
    6
  • fYear
    2013
  • fDate
    Dec-13
  • Firstpage
    2158
  • Lastpage
    2164
  • Abstract
    Gas insulated switchgears (GIS) have been widely used due to their high reliability, low maintenance and compact size. The field experiment is an important step to ensure the safety of GIS. The AC withstand voltage test and its corresponding partial discharge (PD) measurement are inadequate for the detection of all the hidden flaws in GIS. Such inadequacy can be compensated by additional impulse withstand voltage test and its PD detection measurement. This paper reports on experiments to study surface discharge over SF6/epoxy under impulse voltage. The TJ (triple-junction) model was used to study the characteristic of partial discharge (PD). The PD signals under four types of impulse voltages were detected by electrical methods. The 50% probability PD inception voltage (PDIV50), time lags and maximum discharge magnitude were analyzed as a function of gas pressure. The PD characteristics under AC voltage were investigated for comparison. The results indicate that the PD signals under impulse voltage can be detected using electrical method, the number of discharges under oscillating impulse voltage was significantly larger, which was due to the influence of source oscillation. The oscillating lightning impulse has the lowest impulse ratio and it is recommended as the best test waveform choice for the field impulse withstand test with PD detection.
  • Keywords
    SF6 insulation; epoxy insulation; gas insulated switchgear; impulse testing; partial discharge measurement; surface discharges; AC withstand voltage test; GIS safety; PD detection measurement; PD inception voltage; SF6-epoxy interfaces; discharge magnitude; field impulse withstand test; gas insulated switchgear; gas pressure; impulse ratio; oscillating impulse voltage; partial discharge measurement; source oscillation; surface discharge; triple-junction model; Discharges (electric); Lightning; Partial discharges; Sulfur hexafluoride; Voltage measurement; PD inception voltage; Partial discharge; SF6 gas; impulse voltage; oscillating impulse voltage;
  • fLanguage
    English
  • Journal_Title
    Dielectrics and Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1070-9878
  • Type

    jour

  • DOI
    10.1109/TDEI.2013.6678865