• DocumentCode
    1320987
  • Title

    Laplace Transforms for the Two-Unit Cold-Standby Redundant System

  • Author

    Linton, Darrell G. ; Braswell, Robert N.

  • Author_Institution
    Department of Industrial and Systems Engineering, Gainesville, Fla. 32601.
  • Issue
    2
  • fYear
    1973
  • fDate
    6/1/1973 12:00:00 AM
  • Firstpage
    105
  • Lastpage
    108
  • Abstract
    A conditional transform approach is applied to the two-unit standby redundant system with instantaneous switchover, and with failure and repair times that follow general well-behaved distributions for each unit. Transforms of distributions are obtained for T, the time to system failure, the number of repairs completed during T, the time spent on repair during T, and the idle time of the repairman during T. Applicable numerical methods are also discussed.
  • Keywords
    Control systems; Design engineering; Electric breakdown; Electrical equipment industry; Instruments; Laplace equations; Maintenance engineering; Reliability engineering; Statistical analysis; Weight control;
  • fLanguage
    English
  • Journal_Title
    Reliability, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9529
  • Type

    jour

  • DOI
    10.1109/TR.1973.5216044
  • Filename
    5216044