DocumentCode :
1321465
Title :
Reliability Criteria when Standardizing High Contact Density Connectors
Author :
Chaintron, Alain P. ; Mazard, Patrice J.
Author_Institution :
Souriau, 92 Boulogne, France.
Issue :
4
fYear :
1971
Firstpage :
249
Lastpage :
253
Abstract :
The following paper presents the results of a comparative reliability study conducted on three tpes of high density circular connectors, conforming to NAS 1599, MIL. C. 38 999, and MIL. C. 81 511. After runing numerous relability tests, Souriau has been able to develop a highly successful high density connector.
Keywords :
Circuits; Connectors; Contacts; Hardware; Insulation; Power cables; Reliability engineering; Sockets; Testing; Volume measurement;
fLanguage :
English
Journal_Title :
Reliability, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9529
Type :
jour
DOI :
10.1109/TR.1971.5216144
Filename :
5216144
Link To Document :
بازگشت