DocumentCode
1321595
Title
Light flicker test in the United States
Author
Fei, Renyan W. ; Lloyd, Jerry D. ; Crapo, Alan D. ; Dixon, Sharon
Author_Institution
Emerson Motor Co., St. Louis, MO, USA
Volume
36
Issue
2
fYear
2000
Firstpage
438
Lastpage
443
Abstract
Home appliances, like washers, dryers, refrigerators, etc., can cause voltage fluctuations and light flicker. A standardized flicker test has been established in Europe (IEC 1000-3-3). However, the European test is designed for 230-V 50-Hz power and needs to be modified for a 115-V 60-Hz supply. In this paper, the reference impedance and the limits of flicker tests for 115 V/60 Hz systems are proposed. A high-performance power analysis system, the Xitron 2803AH power analyzer, was used to study the voltage fluctuations and flicker caused by some washing machines. The analysis and test results provided in this paper can serve as a proposal for establishing a US light flicker testing standard for 115 V/60 Hz
Keywords
IEC standards; domestic appliances; lighting; power supply quality; power system measurement; voltage measurement; 115 V; 60 Hz; IEC 1000-3-3; United States; Xitron 2803AH power analyzer; dryers; flicker tests limits; high-performance power analysis system; home appliances; light flicker test; reference impedance; refrigerators; standardized flicker test; voltage fluctuations; washers; washing machines; Europe; Home appliances; IEC standards; Impedance; Lamps; Power supplies; Refrigerators; System testing; Voltage fluctuations; Washing machines;
fLanguage
English
Journal_Title
Industry Applications, IEEE Transactions on
Publisher
ieee
ISSN
0093-9994
Type
jour
DOI
10.1109/28.833759
Filename
833759
Link To Document