Steady state analysis of a high-frequency inverter using LCC type load commutation
Author
Bhat, Ashoka K. S. ; Dewan, S.B.
Author_Institution
Department of Electrical Engineering, University of Victoria, Victoria, B.C.
Volume
13
Issue
2
fYear
1988
Firstpage
74
Lastpage
79
Abstract
The object of this paper is to present the steady state analysis of a high-frequency resonant (load commutated) inverter which employs LCC type commutation circuit. The different modes of operation are explained. Fourier analysis method is used to analyze the circuit under steady state conditions, for continuous current mode of operation. The analysis is used to predict the performance of the inverter and to develop the design curves for the selection of inverter components. A simple design procedure is presented and illustrated by a design example. A computer program was developed to evaluate the performance of the inverter and test results are compared with the results obtained from a prototype experimental unit.
Keywords
Capacitors; Harmonic analysis; Impedance; Inductors; Inverters; Resonant frequency; Steady-state;
fLanguage
English
Journal_Title
Electrical and Computer Engineering, Canadian Journal of
Publisher
ieee
ISSN
0840-8688
Type
jour
DOI
10.1109/CJECE.1988.6592779
Filename
6592779