DocumentCode :
1322853
Title :
Evaluation of Harmonic Signals for the Detection of Magnetic Nanoparticles
Author :
Yoshida, T. ; Othman, N.B. ; Tsubaki, T. ; Takamiya, J. ; Enpuku, K.
Author_Institution :
Dept. of Electr. & Electron. Eng., Kyushu Univ., Fukuoka, Japan
Volume :
48
Issue :
11
fYear :
2012
Firstpage :
3788
Lastpage :
3791
Abstract :
We have evaluated the use of harmonic signals for detecting magnetic nanoparticles (MNPs) in biomedical applications. We studied the relationship between the harmonic signals and the distribution of magnetic moments in MNP samples. We measured the harmonic signals and frequency dependence of the ac susceptibility along with static M-H curves. These experimental results were analyzed to obtain the magnetic moment distribution in real samples. We were able to clarify what proportion of MNPs contributes to the harmonic signal. MNPs could be classified according to three types. Type-1 contributes to the fundamental signal only. Type-2 contributes to both the fundamental and harmonic signals. Finally, Type-3 does not contribute to any signals. It is important to choose a sample having a large portion of Type-2 MNPs for the harmonic signal-based detection.
Keywords :
biomedical materials; magnetic moments; magnetic particles; magnetic susceptibility; medical signal detection; medical signal processing; nanoparticles; MNP; ac susceptibility; harmonic signal detection; magnetic moments; magnetic nanoparticles; signal classification; Harmonic analysis; Magnetic moments; Magnetic resonance imaging; Magnetic susceptibility; Nanoparticles; Suspensions; Bionanotechnology; medical diagnostic imaging; nanoparticles; nonlinear magnetics;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/TMAG.2012.2198198
Filename :
6333021
Link To Document :