• DocumentCode
    1322932
  • Title

    Impulse-Peak Measurement by Means of Pulse-Lengthener Circuit With Source Follower

  • Author

    Uno, Masami

  • Author_Institution
    Faculty of Engineering, Shizuoka University, Johoku, Hamamatsu, Japan.
  • Issue
    3
  • fYear
    1971
  • Firstpage
    143
  • Lastpage
    146
  • Abstract
    A method of measuring peak voltage of an impulse by a cascaded two-stage pulse-lengthener circuit followed by a source follower is described. The method permits the measurement of the peak voltage of an impulse with a width as narrow as 15 ns. The measurable peak voltage ranges from +1 to +5 V. The 1 percent decay time of the meter reading is about 5 s. The meter can therefore be read without hurry.
  • Keywords
    Capacitance; Equations; Mathematical model; Pulse measurements; Time measurement; Voltage measurement; Voltmeters;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.1971.5570715
  • Filename
    5570715