DocumentCode
1323073
Title
Direct-Reading Method for Nonlinearity Index of Silicon Carbide Varistor
Author
Uno, Masami ; Tanaka, Hiroyuki
Author_Institution
Faculty of Engineering, Shizuoka University, Hamamatsu, Japan.
Issue
1
fYear
1971
Firstpage
64
Lastpage
66
Abstract
This paper presents a direct-reading method for the nonlinearity index of silicon carbide varistor. Varistors of voltage rated from 50 V to 700 V can be measured without range switching. Measurement is made either at 0.1 and 1 mA or 1 and 10 mA of the varistor current. Precalibration is made by using an ordinary resistor. Measurement accuracy is -3 percent.
Keywords
Current measurement; Indexes; Silicon carbide; Time measurement; Varistors; Voltage measurement; Voltmeters;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/TIM.1971.5570744
Filename
5570744
Link To Document