Incoherent-scatter computed tomography with monochromatic synchrotron x ray: feasibility of multi-CT imaging system for simultaneous measurement-of fluorescent and incoherent scatter x rays
Author :
Yuasa, Tetsuya ; Akiba, Masahiro ; Takeda, Tohoru ; Kazama, Masahiro ; Hoshino, Atsunori ; Watanabe, Yuuki ; Hyodo, Kazuyuki ; Dilmanian, F. Avraham ; Akatsuka, Takao ; Itai, Yuji
Author_Institution :
Fac. of Eng., Yamagata Univ., Yonezawa, Japan
Volume :
44
Issue :
5
fYear :
1997
fDate :
10/1/1997 12:00:00 AM
Firstpage :
1760
Lastpage :
1769
Abstract :
We describe a new system of incoherent scatter computed tomography (ISCT) using monochromatic synchrotron X rays, and we discuss its potential to be used in in vivo imaging for medical use. The system operates on the basis of computed tomography (CT) of the first generation. The reconstruction method for ISCT uses the least squares method with singular value decomposition. The research was carried out at the BLNE-5A bending magnet beam line of the Tristan Accumulation Ring in KEK, Japan. An acrylic cylindrical phantom of 20-mm diameter containing a cross-shaped channel was imaged. The channel was filled with a diluted iodine solution with a concentration of 200 μgI/ml. Spectra obtained with the system´s high purity germanium (HPGe) detector separated the incoherent X-ray line from the other notable peaks, i.e., the iKα and Kβ1 X-ray fluorescent lines and the coherent scattering peak. CT images were reconstructed from projections generated by integrating the counts In the energy window centering around the incoherent scattering peak and whose width was approximately 2 keV. The reconstruction routine employed an X-ray attenuation correction algorithm. The resulting image showed more homogeneity than one without the attenuation correction
Keywords :
Monte Carlo methods; computerised tomography; diagnostic radiography; germanium radiation detectors; image reconstruction; least squares approximations; medical image processing; singular value decomposition; BLNE-5A bending magnet beam line; Ge; Tristan Accumulation Ring; X-ray attenuation correction algorithm; X-ray fluorescent lines; acrylic cylindrical phantom; coherent scattering peak; cross-shaped channel; diluted iodine solution; in vivo imaging; incoherent X-ray line; incoherent scatter computed tomography; incoherent scattering peak; incoherent-scatter computed tomography; least squares method; monochromatic synchrotron X ray; reconstruction method; reconstruction routine; singular value decomposition; Attenuation; Biomedical imaging; Computed tomography; Image reconstruction; In vivo; Least squares methods; Reconstruction algorithms; Synchrotrons; X-ray imaging; X-ray scattering;