DocumentCode :
1325693
Title :
Factors affecting and methods of improving the pulse repetition frequency of pulse-charged and DC-charged high-pressure gas switches
Author :
MacGregor, Scott J. ; Turnbull, Steven M. ; Tuema, Fadhil A. ; Farish, Owen
Author_Institution :
Dept. of Electron. & Electr. Eng., Strathclyde Univ., Glasgow, UK
Volume :
25
Issue :
2
fYear :
1997
fDate :
4/1/1997 12:00:00 AM
Firstpage :
110
Lastpage :
117
Abstract :
The results of this paper describe some of the factors which affect the repetitive operation of high-pressure gas switches (spark gaps) for both pulse-charged and DC-charged operation. Also discussed are methods which may be employed to improve the pulse repetition frequency (PRF) of spark gaps operating under such conditions. Under pulse-charged conditions, the voltage recovery process of the spark gap has been shown to be restricted following partial density recovery by the residual ion population. This restriction may be minimized by applying a suitable bias voltage across the gap to remove the ion influence. It is also possible to manipulate the voltage-pressure (V-p) breakdown characteristic of a spark gap in order to improve the rate of rise of recovery voltage by reducing the recovery voltage dependence upon gas pressure. The combination of these effects has been shown to reduce the voltage recovery time of pulse-charged spark gaps from several hundred milliseconds to several milliseconds. Under DC-charged conditions, where no “dead time” is available for voltage recovery, it is possible to employ corona discharge effects, which occur in highly nonuniform fields, to stabilize and control the breakdown process. The use of corona stabilization has enabled the operation of a self-closing spark gap at a PRF of more than 5 kHz, without employing gas flow techniques. A triggered version of a corona-stabilized spark gap has also been developed which has demonstrated single run capabilities of 107 (4 h continuous operation at 700 pps) and a lifetime of ~10 shots (maintenance free, sealed switch). The triggered corona switch has also demonstrated controlled switching up to a PRF of 1.2 kHz
Keywords :
corona; pulse frequency modulation; pulsed power switches; spark gaps; 1.2 kHz; 5 kHz; DC-charged high-pressure gas switches; bias voltage; corona discharge effects; dead time; gas pressure dependence; highly nonuniform fields; ion effects; maintenance-free lifetime; partial density recovery; pulse repetition frequency; pulse-charged high-pressure gas switches; recovery voltage rise time; repetitive operation; residual ion population; self-closing spark gap; single run capabilities; spark gaps; triggered corona switch; triggered corona-stabilized spark gap; voltage recovery process; voltage-pressure breakdown characteristic; Breakdown voltage; Corona; Fluid flow; Frequency; Process control; Pulse measurements; Pulse modulation; Spark gaps; Switches; Voltage control;
fLanguage :
English
Journal_Title :
Plasma Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-3813
Type :
jour
DOI :
10.1109/27.602480
Filename :
602480
Link To Document :
بازگشت