DocumentCode :
1328881
Title :
A Low-Cost Electrochemical Biosensor for Rapid Bacterial Detection
Author :
Nandakumar, Vivek ; Bishop, Daniel ; Alonas, Eric ; LaBelle, Jeffrey ; Joshi, Lokesh ; Alford, Terry L.
Author_Institution :
Sch. of Electr., Comput. & Energy Eng., Arizona State Univ., Tempe, AZ, USA
Volume :
11
Issue :
1
fYear :
2011
Firstpage :
210
Lastpage :
216
Abstract :
A three-electrode electrochemical biosensor has been developed using printed circuit boards for detecting bacterial contamination. This low-cost, small-size device consists of thin-film gold electrodes and is fabricated using photo-lithography paired with electro-deposition. Pathogen presence is deduced by detection of change in electrical impedance caused by binding of the pathogen to bio-receptors coated on the sensor surface. The biosensor has a total area of 3.2 cm and requires only 100 L of test sample for detection. The sensor geometry has been optimized using techniques from Design of Experiments, and the device can be operated using a small ac excitation potential of magnitude 5 mV. The sensor is tested on the common food-borne pathogen Salmonella typhimurium and is able detect bacterial concentrations of the order of 500 CFU/mL within 6 min. In this paper, the design and fabrication of the biosensor is detailed along with the experiments that validate its performance.
Keywords :
biosensors; electric impedance; electrochemical electrodes; electrochemical sensors; food safety; gold; metallic thin films; microorganisms; photolithography; printed circuits; Au; Salmonella typhimurium; ac excitation potential; bacterial contamination; bacterial detection; bio-receptors; electrical impedance; electro-deposition; food-borne pathogen; low-cost electrochemical biosensor; pathogen binding; photo-lithography; printed circuit boards; sensor surface; thin-film gold electrodes; three-electrode electrochemical biosensor; time 6 min; voltage 5 mV; Biosensors; Electrodes; Fabrication; Impedance; Microorganisms; Pathogens; Surface impedance; Biomedical transducers; design automation; electrochemical processes; impedance measurement;
fLanguage :
English
Journal_Title :
Sensors Journal, IEEE
Publisher :
ieee
ISSN :
1530-437X
Type :
jour
DOI :
10.1109/JSEN.2010.2055847
Filename :
5580000
Link To Document :
بازگشت