• DocumentCode
    1330253
  • Title

    Magnetostrictive metallic glass ribbon gradiometer

  • Author

    Mermelstein, M.D. ; Dandridge, A.

  • Author_Institution
    Naval Res. Lab., Washington, DC
  • Volume
    24
  • Issue
    14
  • fYear
    1988
  • fDate
    7/7/1988 12:00:00 AM
  • Firstpage
    895
  • Lastpage
    896
  • Abstract
    A new magnetic field gradiometer has been demonstrated which exhibits a minimum detectable field gradient of 7.7 pT/cm√(Hz) at 1.0 Hz. The sensor element utilises a single metallic glass ribbon thereby enhancing common-mode rejection of noise and providing a compact probe. Balancing is currently achieved by adjusting the individual amplifier gains. However, configuring the pick-up coils in series opposition in a sensor exhibiting an improved uniformity of response may obviate the need for this additional signal processing
  • Keywords
    electric sensing devices; magnetic field measurement; magnetometers; magnetostrictive devices; amorphous type; compact probe; magnetic field gradiometer; metallic glass ribbon; pick-up coils; piezoelectric plate; sensor element; series opposition; stress driven magnetoelastic type;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • Filename
    8410