• DocumentCode
    1334373
  • Title

    Fascicle-Selectivity of an Intraneural Stimulation Electrode in the Rabbit Sciatic Nerve

  • Author

    Nielsen, Thomas N. ; Sevcencu, Cristian ; Struijk, Johannes J.

  • Author_Institution
    Dept. of Health Sci. & Technol., Aalborg Univ., Aalborg, Denmark
  • Volume
    59
  • Issue
    1
  • fYear
    2012
  • Firstpage
    192
  • Lastpage
    197
  • Abstract
    The current literature contains extensive research on peripheral nerve interfaces, including both extraneural and intrafascicular electrodes. Interfascicular electrodes, which are in-between these two with respect to nerve fiber proximity have, however, received little interest. In this proof-of-concept study, an interfascicular electrode was designed to be implanted in the sciatic nerve and activate the tibial and peroneal nerves selectively of each other, and it was tested in acute experiments on nine anaesthetized rabbits. The electrode was inserted without difficulty between the fascicles using blunt glass tools, which could easily penetrate the epineurium but not the perineurium. Selective activation of all tibial and peroneal nerves in the nine animals was achieved with high selectivity (Ŝ = 0.98 ± 0.02). Interfascicular electrodes could provide an interesting addition to the bulk of peripheral nerve interfaces available for neural prosthetic devices. Since interfascicular electrodes can be inserted without fully freeing the nerve and have the advantage of not confining the nerve to a limited space, they could, e.g., be an alternative to extraneural electrodes in locations where such surgery is complicated due to blood vessels or fatty tissue. Further studies are, however, necessary to develop biocompatible electrodes and test their stability and safety in chronic experiments.
  • Keywords
    biomedical electrodes; neurophysiology; prosthetics; anaesthetized rabbits; biocompatible electrodes; blunt glass tool; chronic experiment; epineurium; extraneural electrode; fiber proximity; intrafascicular electrode; intraneural stimulation electrode fascicle-selectivity; neural prosthetic device; peripheral nerve interface; peroneal nerve; rabbit sciatic nerve; sciatic nerve; tibial nerve; Animals; Electrodes; Electron tubes; Glass; Impedance; Impedance measurement; Nerve fibers; Animal experiments; interfascicular electrode; nerve stimulation; peripheral nerves; stimulation selectivity; Action Potentials; Animals; Differential Threshold; Electric Stimulation; Electrodes, Implanted; Equipment Design; Equipment Failure Analysis; Nerve Fibers; Rabbits; Sciatic Nerve; Sensitivity and Specificity;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2011.2169671
  • Filename
    6029418