DocumentCode
1334373
Title
Fascicle-Selectivity of an Intraneural Stimulation Electrode in the Rabbit Sciatic Nerve
Author
Nielsen, Thomas N. ; Sevcencu, Cristian ; Struijk, Johannes J.
Author_Institution
Dept. of Health Sci. & Technol., Aalborg Univ., Aalborg, Denmark
Volume
59
Issue
1
fYear
2012
Firstpage
192
Lastpage
197
Abstract
The current literature contains extensive research on peripheral nerve interfaces, including both extraneural and intrafascicular electrodes. Interfascicular electrodes, which are in-between these two with respect to nerve fiber proximity have, however, received little interest. In this proof-of-concept study, an interfascicular electrode was designed to be implanted in the sciatic nerve and activate the tibial and peroneal nerves selectively of each other, and it was tested in acute experiments on nine anaesthetized rabbits. The electrode was inserted without difficulty between the fascicles using blunt glass tools, which could easily penetrate the epineurium but not the perineurium. Selective activation of all tibial and peroneal nerves in the nine animals was achieved with high selectivity (Ŝ = 0.98 ± 0.02). Interfascicular electrodes could provide an interesting addition to the bulk of peripheral nerve interfaces available for neural prosthetic devices. Since interfascicular electrodes can be inserted without fully freeing the nerve and have the advantage of not confining the nerve to a limited space, they could, e.g., be an alternative to extraneural electrodes in locations where such surgery is complicated due to blood vessels or fatty tissue. Further studies are, however, necessary to develop biocompatible electrodes and test their stability and safety in chronic experiments.
Keywords
biomedical electrodes; neurophysiology; prosthetics; anaesthetized rabbits; biocompatible electrodes; blunt glass tool; chronic experiment; epineurium; extraneural electrode; fiber proximity; intrafascicular electrode; intraneural stimulation electrode fascicle-selectivity; neural prosthetic device; peripheral nerve interface; peroneal nerve; rabbit sciatic nerve; sciatic nerve; tibial nerve; Animals; Electrodes; Electron tubes; Glass; Impedance; Impedance measurement; Nerve fibers; Animal experiments; interfascicular electrode; nerve stimulation; peripheral nerves; stimulation selectivity; Action Potentials; Animals; Differential Threshold; Electric Stimulation; Electrodes, Implanted; Equipment Design; Equipment Failure Analysis; Nerve Fibers; Rabbits; Sciatic Nerve; Sensitivity and Specificity;
fLanguage
English
Journal_Title
Biomedical Engineering, IEEE Transactions on
Publisher
ieee
ISSN
0018-9294
Type
jour
DOI
10.1109/TBME.2011.2169671
Filename
6029418
Link To Document