DocumentCode
1335452
Title
Convex Optimization of Coincidence Time Resolution for a High-Resolution PET System
Author
Reynolds, Paul D. ; Olcott, Peter D. ; Pratx, Guillem ; Lau, Frances W.Y. ; Levin, Craig S.
Author_Institution
Dept. of Electr. Eng., Stanford Univ., Stanford, CA, USA
Volume
30
Issue
2
fYear
2011
Firstpage
391
Lastpage
400
Abstract
We are developing a dual panel breast-dedicated positron emission tomography (PET) system using LSO scintillators coupled to position sensitive avalanche photodiodes (PSAPD). The charge output is amplified and read using NOVA RENA-3 ASICs. This paper shows that the coincidence timing resolution of the RENA-3 ASIC can be improved using certain list-mode calibrations. We treat the calibration problem as a convex optimization problem and use the RENA-3´s analog-based timing system to correct the measured data for time dispersion effects from correlated noise, PSAPD signal delays and varying signal amplitudes. The direct solution to the optimization problem involves a matrix inversion that grows order (n3) with the number of parameters. An iterative method using single-coordinate descent to approximate the inversion grows order (n). The inversion does not need to run to convergence, since any gains at high iteration number will be low compared to noise amplification. The system calibration method is demonstrated with measured pulser data as well as with two LSO-PSAPD detectors in electronic coincidence. After applying the algorithm, the 511 keV photopeak paired coincidence time resolution from the LSO-PSAPD detectors under study improved by 57%, from the raw value of 16.3 ± 0.07 ns full-width at half-maximum (FWHM) to 6.92 ±0.02 ns FWHM (11.52 ±0.05 ns to 4.89 ± 0.02 ns for unpaired photons).
Keywords
application specific integrated circuits; avalanche photodiodes; biomedical electronics; calibration; convergence of numerical methods; gynaecology; iterative methods; optimisation; positron emission tomography; LSO scintillators; LSO-PSAPD detectors; NOVA RENA-3 ASICs; analog-based timing system; charge output; coincidence time resolution; convex optimization; correlated noise; dual panel breast-dedicated positron emission tomography; electron volt energy 511 keV; high-resolution PET SYSTEM; iterative method; list-mode calibrations; matrix inversion; position sensitive avalanche photodiodes; single-coordinate descent; system calibration method; time dispersion effects; Calibration; Crystals; Delay; Noise; Photonics; Shape; Coincidence; PSAPD; convex; positron emission tomography; time resolution; Algorithms; Calibration; Models, Theoretical; Positron-Emission Tomography; Signal Processing, Computer-Assisted;
fLanguage
English
Journal_Title
Medical Imaging, IEEE Transactions on
Publisher
ieee
ISSN
0278-0062
Type
jour
DOI
10.1109/TMI.2010.2080282
Filename
5585771
Link To Document